CHAPTER 6 PG-FP4 OPERATION IN STANDALONE MODE
6.1.3
[Option Setting] menu
The [Option Setting] menu is used to check the command option and security flag currently set for the PG-FP4. All
the displayed values were set during the last programming session.
The setting cannot be changed on this menu.
[Option Setting >]
? Pressing the Next button displays the [Voltage Setting] menu.
? Pressing the Enter button displays the following commands that can be executed on the [Option Setting] menu.
? Pressing the Cancel button displays the [Commands] menu again.
[ BLN before ERS ] Displays the set status of the command option Blank check before Erase as either of the
following.
on: Blank check is executed before execution of the Erase and EPV commands.
If the result of the blank check is OK, erasure processing is not executed.
off: Blank check is not executed before execution of the Erase and EPV commands.
↓ Next button
[ VRF after PRG ]
Displays the set status of the command option Verify after Program as either of the following.
on: After execution of the Program and EPV commands, the write data is transmitted
from the programmer and verified against the data written to the flash memory.
off: After execution of the Program and EPV commands, the data transmitted from the
programmer is not verified against the data written to the flash memory.
↓ Next button
[ SCF after PRG ]
Displays the set status of the command option Security flag after Program as either of the
following Note .
on: After execution of the Program and EPV commands, the security flag selected by
Security flag settings is automatically set.
off: After execution of the Program and EPV commands, the security flag is not
automatically set.
↓ Next button
[ SUM after PRG ]
Displays the set status of the command option Checksum after Program as either of the
following Note .
on: After execution of the Program and EPV commands, the flash memory checksum
value of the target device is read from the target device and displayed on the
programmer.
off: After execution of the Program and EPV command, the flash memory checksum
value of the target device is neither read nor displayed.
↓ Next button
(continued on next page)
Note This menu is displayed only when a single-power-supply flash memory microcontroller is used.
User ’s Manual U15260EJ4V0UM
83
相关PDF资料
PG15S-D20-HHB9 MOTOR GEARED STEPPER 15MM 15V BI
PG164120 PROGRAMMER MCU PICKIT 2
PG20L-D20-HHC0 MOTOR GEARED STEPPER 20MM 10V BI
PG25L-D24-HHC1 MOTOR GEARED STEPPER 25MM 24V BI
PG35S-D48-HHC2 MOTOR GEARED STEPPER 35MM 24V BI
PIC12F683 DEVELOPMENT KIT KIT DEV EMBEDDED C
PIC18F4520 DEVELOPMENT KIT KIT DEV EMBEDDED C
PIC18F67J10 DEVELOPMENT KIT KIT DEV EMBEDDED C
相关代理商/技术参数
PG-FP5 制造商:Renesas Electronics Corporation 功能描述:MCU,Programmer,NEC Flash MCU
PG-FP5-AS 制造商:Renesas Electronics Corporation 功能描述:MICROCOMPUTER FLASH MEMORY PROGRAMMER 制造商:Renesas Electronics Corporation 功能描述:PROGRAMMER FLASH RL78 V850 7
PG-FP5-EA 功能描述:PROGRAMMER FLASH MEMORY UNIV RoHS:是 类别:编程器,开发系统 >> 内电路编程器、仿真器以及调试器 系列:* 产品变化通告:Development Systems Discontinuation 19/Jul/2010 标准包装:1 系列:* 类型:* 适用于相关产品:* 所含物品:*
PGFP-A11 功能描述:PLUG GFCI 120VAC 15/20A AUTORST RoHS:是 类别:过电压,电流,温度装置 >> 接地故障电路断路器 (GFCI) 系列:PGFP 标准包装:1 系列:PGFI 类型:带 6 英尺引线的直列接头 技术规格:120V 其它名称:723-1041
PGFP-A110KYST2 功能描述:CORD GFCI 120VAC 2' YEL SNG TAP RoHS:是 类别:过电压,电流,温度装置 >> 接地故障电路断路器 (GFCI) 系列:PGFP 标准包装:1 系列:PGFI 类型:带 6 英尺引线的直列接头 技术规格:120V 其它名称:723-1041
PGFP-A110KY-ST2 制造商:Airpax 功能描述:
PGFP-A110KYST25 功能描述:CORD GFCI 120VAC 25' YEL SNG RoHS:是 类别:过电压,电流,温度装置 >> 接地故障电路断路器 (GFCI) 系列:PGFP 标准包装:1 系列:PGFI 类型:带 6 英尺引线的直列接头 技术规格:120V 其它名称:723-1041
PGFP-A110KYTT2 功能描述:CORD GFCI 120VAC 2' YEL TRITAP RoHS:是 类别:过电压,电流,温度装置 >> 接地故障电路断路器 (GFCI) 系列:PGFP 标准包装:1 系列:PGFI 类型:带 6 英尺引线的直列接头 技术规格:120V 其它名称:723-1041